Desco logo - click to return to home page

Manufacturer of ESD Static Control Products

Full Catalog > Wrist Straps and Coil Cords > Single-Wire Wrist Straps & Coil Cords > Metal Wrist Straps >

09086-WRIST STRAP, PREMIUM METAL EXP LARGE, 1.8M CORD, 4MM

09086-WRIST STRAP, PREMIUM METAL EXP LARGE, 1.8M CORD, 4MM              

09086 - Large Metal Adjustable Wrist Strap with 1.8m Cord, 4mm

List Price
1 $52.75

2 In Stock.

Stock Location: YACHIMATA CITY, CHIBA

Country Of Origin: USA

Sold Per: EA

Gross Weight2: 0.08 kg

2The weight listed is gross product weight including standard packaging, actual shipment weight may vary.

Quantity:


 



Bookmark and Share
 
  • Premium metal expansion wrist strap with more reliable path-to-ground*
    Comfortable, designed not to pinch or pull hair
  • Durable metal band
    Long wearing, easy to clean
  • Superior contact with skin
    For reliable removal of generated static charges
  • Non-flaking or scratching laminated insulator on all external surfaces
    Protects wearers from electrical hazards Provides many years of product life
  • Medical grade stainless steel interior expansion band
    Will not cause allergic skin reactions for most people
  • Date coded
    Providing lot tractability to ensure quality control
  • Made in the United States of America

What the ESD Association says about wrist straps:
* "Note: Metal expansion bracelet style wrist cuffs may trap moisture underneath and can be more effective for people with dry skin." [ESD Handbook TR20.20 section 5.3.2.4.3]

Per ESD Handbook TR20.20 section 5.3.9.1 Wrist Strap Checkers - “Wrist strap checkers have historically been the primary tool for testing the operation of the wrist strap system including, the wristband, grounding cord and most importantly, the electrical integrity of the contact between the wristband and the wearer. Wrist strap checkers measure the resistance of the entire system.”

Circumference - Extra large: 6.25" - 14.5"
NOTE: All bands have a 4mm snap stud. Complete wrist strap kits include an alligator clip. Wrist strap kits include an alligator clip for occasions when a grounded banana jack is not available. However, best industry practice is that ESD Ground Connections should be firm fitting connecting devices such as metallic crimps, snaps and banana plugs to be connected to designated ground points. Use of alligator clips is not recommended. (Ref: JEDEC Standard No. 625-A)

ANSI/ESD S20.20 Paragraph 6.2.2.1 Personnel Grounding Requirement "All personnel shall be bonded or electrically connected to ground or contrived ground when handling ESD sensitive items. When personnel are seated at ESD protective workstations, they shall be connected to the common point via a wrist strap system."

Reliable Path-to-Ground: Are You Wasting the Money Spent on ESD Control? How Many Accidental Disconnects Occur a Day at Your Plant Putting Your Products at Risk? Read the Evaluation Engineering Magazine Article, "Solving the Wristband Snap Release Problem"
*Reproduced with Permission,
EE-Evaluation Engineering, June, 2001

For dry skin conditions, see
Reztore ESD Hand Lotion

Show more details...
Hide details...
  • TB-2005 - Wrist Straps Grounding - Testing and Maintenance
  • 09043 - Premium Fixed Size Metal Expansion Wrist Straps
  • 09480 - Relaxed Retraction Coil Cord