- Relay time for door locking systems, password protection
- Enables users to easily connect to automated door openers
- Independent alarming conditions
- Audio and visual alarms if the total resistance is below, within, or exceeds the user limits
- Split footplate design
- Allows for individual footwear testing all in one test
- Saves operator time by testing once and having all tests and results with one touch of a button
- Calibrate with the 50401 Limit Comparator
- Made in America
“Compliance verification should be performed prior to each use (daily, shift change, etc.). The accumulation of insulative materials may increase the foot grounder system resistance. If foot grounders are worn outside the ESD protected area testing for functionality before reentry to the ESD protected area should be considered.” (ESD SP9.2 APPENDIX B - Foot Grounder Usage Guidance)
“A log should be maintained which verifies that personnel have tested their personal grounding devices.” (ANSI/ESD S20.20 Paragraph 6.2.2.2 Personnel Grounding Guidance)
“Frequency of Functional Testing: The wrist strap system should be tested daily to ensure proper electrical value. Nominally, the upper resistance reading should be < or = 10 megohms or a user-defined value.” (ANSI/ESD S1.1-2006 Annex A3)