07501 - Sole Grounder, Small, 2 Megohm Resistor

List Price
1 $29.19

8 In Stock.

Stock Location: YACHIMATA CITY, CHIBA

Country Of Origin: USA

Sold Per: EA

Gross Weight2: 0.05 kg

2The weight listed is gross product weight including standard packaging, actual shipment weight may vary.

Quantity:


 



Bookmark and Share
  • Large Contact Area on Ball of Foot
    The combination of additional surface area and the contact point on the ball of the foot forms a more consistent path to ground.
  • Tear Resistant Rubber With Inner Scrim
    Reinforced material prevents material from tearing – increasing the service life
  • Hook and Loop Stretch Hook And Loop Fastening System
    Size adjustable material expands to fit most shoe sizes comfortably and flex during walking
  • 30" Long, 8 Conductive Strand Nylon Polyester Grounding Tab
    Additional conductive material provides reliable connection with operator’s sweat-layer
  • Two Megohm Series Resistor
    To protect operator from accidental contact with equipment line voltage
  • UL Listed
    Independently reviewed for adequacy of the product's design
  • RG: 1 x 106 to < 1 x108 ohms per ESD SP9.2 7 ESD TR53
  • Date Coded
    Provides lot traceability to ensure quality control and tracking information
  • Made In The United States of America

Per ESD SP9.2 APPENDIX B - Foot Grounder Usage Guidance “Compliance verification should be performed prior to each use (daily, shift change, etc.). The accumulation of insulative materials may increase the foot grounder system resistance. If foot grounders are worn outside the ESD protected area testing for functionality before reentry to the ESD protected area should be considered.”

Per ANSI/ESD S20.20 Paragraph 6.2.2.2 Personnel Grounding Guidance, “ESD protective flooring, used with approved footwear, may be used as an alternative to the wrist strap system for standing operations.”

ESD Handbook TR 20.20 paragraph 5.2.3 “If the contact area between the bottom of the foot and the floor is not continuous, charge generation may occur especially when a person is walking. Heel straps must be worn on both feet to minimize the amount of time that the body of the person is isolated from ground while walking.”

Suitable for ESD footwear component in Flooring - Footwear System personnel grounding method (<3.5 x 107 ohms per ESD STM 97.1).
Suitable for ESD footwear component in flooring - Footwear System personnel grounding method (<100 volts per ESD STM 97.2).

 

Show more details...
Hide details...
  • TB-2020 - Foot Grounders - Grounding, Testing, and Maintenance